Multi Stage Centrifugal Pump Test Setup
Product Code : EL-HML-11054
The Multi Stage Centrifugal Pump Test Setup from Lab Exports is a hydraulic machine lab setup that lets students study the performance of two centrifugal pumps connected in series or parallel, comparing speed, head, discharge and efficiency across different pump combinations.
Specifications
| Pumps | 2 nos., Kirloskar, 1 HP each, speed up to 2800 RPM, head up to 12 m |
| Drive | DC drive with non-contact type digital RPM indicator |
| Supply Tank | 150 litre capacity |
| Measuring Tank | 100 litre capacity, fitted with piezometer tube and scale |
| Piping | GI / PVC |
| Stop Watch | Electronic |
| Control Panel | Complete electrical instrumentation |
Key Features
- Two centrifugal pumps that can be connected in series or parallel to simulate different combinations
- Pressure and vacuum gauges on delivery and suction side of each pump for measurement
- Swinging field dynamometer arrangement for direct torque measurement
- Closed-loop water circulation in a compact, stand-alone unit
- Stainless steel tanks and wetted parts for corrosion resistance
- MS Excel sample calculation program available on demand
Applications
The Multi Stage Centrifugal Pump Test Setup is used in hydraulic machinery laboratories to study speed vs. discharge, head vs. discharge at various speeds, and efficiency curves at different speeds and heads, helping students understand how series and parallel pump combinations affect overall system performance.
Why Choose Lab Exports
Lab Exports is a trusted manufacturer and exporter of engineering lab equipment including a complete range of Hydraulic Machine Lab apparatus for engineering colleges and technical institutes. Every unit is built for classroom durability, measurement accuracy and long-term reliability, backed by responsive after-sales support.
Related Products in Hydraulic Machine Lab
- Centrifugal Pump Test Rig
- Pelton Wheel Turbine Test Setup
- Francis Turbine Test Setup
- Hydraulic Machine Lab Equipment
- Engineering Lab Equipment
Frequently Asked Questions
Q1. What does the Multi Stage Centrifugal Pump Test Setup study?
It studies the performance of two centrifugal pumps connected in series or parallel, comparing speed, head, discharge and efficiency.
Q2. How many pumps are included in the setup?
Two Kirloskar-make centrifugal pumps, each 1 HP with speed up to 2800 RPM and head up to 12 m, are included.
Q3. How is torque measured?
A swinging field dynamometer arrangement is used for direct torque measurement.
Q4. What experiments can be performed?
Students can study speed vs. discharge, head vs. discharge at various speeds, and efficiency curves at different speeds and heads.
Q5. What utilities are required to operate the setup?
It requires a 230V ±10VAC, 50Hz, single-phase electric supply with proper earthing, and a tap water connection.
Request a Quote
For pricing, specifications or export documentation on the Multi Stage Centrifugal Pump Test Setup, contact Lab Exports for a detailed quotation.