Spot Check Pulse Oximeter With Accessories
Product Code : EL-MDE-10841
Quick answer: The Spot Check Pulse Oximeter with Accessories is a compact, clip-on pulse oximeter that measures arterial oxygen saturation (SpO2) and pulse rate through a finger or toe for quick checks on neonate, infant and adult patients. It reads SpO2 from 70 to 99% and pulse from 30 to 240 bpm. Lab Exports manufactures it in Delhi for hospitals, clinics and medical colleges.
Specifications
| Parameter | Value |
|---|---|
| Design | Ultra-compact, robust, shock-resistant finger/toe clip |
| Finger/toe fit | 8 to 25 mm directly, or via a separate connectable sensor |
| Patient groups | Neonate, infant and adult |
| SpO2 range | 70 to 99% |
| SpO2 accuracy | ±3% |
| SpO2 resolution | 1% or less |
| Pulse rate range | 30 to 240 bpm |
| Pulse rate accuracy | ±3% |
| Pulse rate resolution | 1 bpm |
| Display | SpO2, pulse rate, signal strength, sensor error/disconnect, low battery |
| Power supply | 2 x 1.5 V AAA batteries; at least 2500 spot checks (30 s each) or 21 hours continuous |
| Operating conditions | 5 to 40 °C, RH 30 to 80% |
| Storage conditions | -20 to 60 °C, RH 10 to 95% |
How it is used
Pulse oximetry shines red and infrared light through a finger or toe and measures how much of each is absorbed. Oxygenated and deoxygenated haemoglobin absorb the two wavelengths differently, so their ratio gives the oxygen saturation, while the pulsing change in absorption with each heartbeat gives the pulse rate.
This model is built for spot checks rather than continuous bedside monitoring: a reading takes about 30 seconds and the clip then comes off. Its pocket-sized, shock-resistant body suits ward rounds, outpatient triage, emergency care and outreach work, and the separate connectable sensor covers fingers or toes outside the 8 to 25 mm clip range.
- Switch on the oximeter and check the low-battery indicator.
- Place the clip on a clean, warm finger or toe, or connect the separate sensor.
- Keep the patient still and wait for the signal-strength display to settle.
- Read SpO2 and pulse rate, remove the clip and let the unit power itself off.
Key features
- Suitable for professional clinical use on neonate, infant and adult patients
- SpO2 range 70 to 99% with ±3% accuracy and 1% resolution
- Pulse rate range 30 to 240 bpm with 1 bpm resolution
- Shows signal strength, sensor error or disconnect, and low battery
- Two AAA cells give at least 2500 spot checks or 21 hours of continuous use, with automatic power-off
- Robust, shock-resistant ultra-compact housing that fits in a pocket
Documentation and supply
An operating manual is supplied with the oximeter. Most Lab Exports products carry a one-year manufacturer warranty.
Lab Exports manufactures the spot check pulse oximeter at its works in Laxmi Nagar, Delhi, and supplies it to hospitals, clinics and medical colleges in India and 60+ countries, handling the export documents for each shipment. More about the company is on the About Lab Exports page.
Related Medical Diagnostic Equipment products
- Non Contact Clinical Thermometer (EL-MDE-10842)
- Handheld Pulse Oximeter Incl. Respiratory (EL-MDE-10855)
- FHR Doppler Detector with Accessories (EL-MDE-10856)
- Portable ECG Recorder w/access (EL-MDE-10857)
- CTG Monitor with Accessories (EL-MDE-10858)
- Tape Measure Fibreglass Tailors (EL-MDE-10859)
The full range is in the Medical Diagnostic Equipment section of the Hospital Lab range.
Frequently asked questions
What does the spot check pulse oximeter measure?
It measures arterial blood oxygen saturation (SpO2) and pulse rate through a non-invasive clip placed on a finger or toe.
What are its measuring ranges?
SpO2 is read from 70 to 99% with ±3% accuracy and 1% resolution; pulse rate is read from 30 to 240 bpm with 1 bpm resolution.
How long do the batteries last?
Two 1.5 V AAA batteries give at least 2500 spot checks of 30 seconds each, or about 21 hours of continuous operation.
What is the price of the spot check pulse oximeter?
Prices are not published on the website. Add the spot check pulse oximeter to the Enquiry Cart with the Add To Cart button on this page, or email [email protected] with the house code EL-MDE-10841 and the quantity, to receive a quotation.
Does Lab Exports manufacture the spot check pulse oximeter?
Yes. Lab Exports manufactures the spot check pulse oximeter at its works at 11/315, Lalita Park, Laxmi Nagar, Delhi 110092, under house code EL-MDE-10841.
Request a quote
Email [email protected] with the house code EL-MDE-10841 and the quantity, or add the spot check pulse oximeter to the Enquiry Cart with the Add To Cart button on this page. Tender buyers can also see the Tenders and OEM page.