HEAT TRANSFER LAB Manufacturer, Suppliers and Exporter in India

Lab Exports is leading HEAT TRANSFER LAB Manufacturer,and supplier and Exporter in India,

Quick answer: Lab Exports is a heat transfer lab equipment manufacturer in India, working from Laxmi Nagar, Delhi, since 1986. The Heat Transfer Lab subcategory lists 16 apparatus with EL-HTL house codes for conduction, insulation, fins, convection, radiation, boiling and heat exchangers, used in mechanical and chemical engineering laboratories in India and 60+ countries.

Heat transfer lab equipment list

ApparatusHouse codeKey specification
Thermal Conductivity of Metal RodEL-HTL-1109425 mm copper bar; 8 thermocouples; water-cooled end
Composite Walls ApparatusEL-HTL-11078250 mm mica heater; mild steel, Bakelite and brass or aluminium plates
Lagged Pipe ApparatusEL-HTL-11079Three concentric GI pipes, 1 m long, with a central cartridge heater
Critical Radius of Insulating MaterialEL-HTL-110814 heated GI pipes with plaster of Paris at different thicknesses
Heat Pipe ApparatusEL-HTL-1108025 mm OD stainless steel heat pipe compared with copper and steel pipes
Pin Fin ApparatusEL-HTL-11082Mild steel, brass and aluminium fins; 5 thermocouples along the fin
Natural Convection ApparatusEL-HTL-11083Brass pipe 38 mm OD, 500 mm long; 7 thermocouples
Forced Convection ApparatusEL-HTL-1108432 mm NB GI test pipe; centrifugal blower with orifice meter
Specific Heat of Air ApparatusEL-HTL-110851 kW heating coil; orifice meter; 0-300 C digital indicator
Heat Transfer in Agitated VesselEL-HTL-11087Approx. 20 litre insulated vessel; 8-turn copper helical coil
Emissivity Measurement ApparatusEL-HTL-11088160 mm aluminium test and black plates with mica heaters
Stefan-Boltzmann ApparatusEL-HTL-11089200 mm copper hemisphere in a water jacket; 20 mm copper test disc
Critical Heat Flux ApparatusEL-HTL-1109035 or 40 gauge test wire in a glass trough; 1 kW nichrome heater
Concentric Tube Heat ExchangerEL-HTL-11091Copper inner tube, 12.7 mm ID; 3 kW geyser
Shell and Tube Heat Exchanger, Water to WaterEL-HTL-110924 baffles with 25% cut; copper tubes; 3 kW heater
Plate Type Heat Exchanger ApparatusEL-HTL-11093Stainless steel plates, 200 x 400 mm; 3 kW geyser

Heat transfer experiments

Conduction experiments find the thermal conductivity of a copper rod from its temperature gradient, the overall resistance of a wall made of three different plates, and the conductivity of the insulation in a lagged pipe. The critical radius apparatus shows how insulation thickness on a heated pipe changes heat loss, and the heat pipe apparatus compares the temperature profile of a heat pipe with solid copper and stainless steel pipes of the same size.

Convection experiments cover the temperature distribution and efficiency of pin fins, the natural convection coefficient of a heated pipe in an enclosure, the forced convection coefficient for air flowing through a heated pipe, the specific heat of air, and the heat transfer coefficient of a helical coil in an agitated vessel. Radiation work measures the emissivity of a test plate against a black plate and the Stefan-Boltzmann constant, the critical heat flux apparatus shows boiling on an electrically heated wire, and the three exchangers are used to find heat transfer rates and effectiveness.

Radiation and heat exchanger specifications

The Stefan-Boltzmann Apparatus (EL-HTL-11089) heats a 200 mm copper hemisphere inside a 250 mm water jacket fed from a tank with an immersion heater; the 20 mm copper test disc has a thermocouple at its centre, the digital indicator reads to 0.1 C, and a buzzer sounds every 5 seconds for timed readings. The Shell and Tube Heat Exchanger (EL-HTL-11092) has a 750 mm shell with end boxes and a divider plate, copper tubes of 6.35 mm OD on a triangular pitch and an instantaneous 3 kW water heater, and needs about 10 litres of water per minute.

Most of the apparatus run on a 230 V AC supply with earthing, and the product pages list the bench or floor area needed. Most Lab Exports products carry a one-year manufacturer warranty.

Heat transfer lab questions

Which heat exchangers are available?

Three: a concentric tube exchanger with a copper inner tube and GI outer pipe, a water-to-water shell and tube exchanger with four baffles, and a plate exchanger with stainless steel plates of 200 x 400 mm. Hot water comes from a 3 kW geyser or heater on each.

Which apparatus cover thermal radiation?

The emissivity apparatus heats a test plate and a black plate, each 160 mm in diameter, with separate dimmers in a Perspex-fronted panel, and the Stefan-Boltzmann apparatus measures the radiation constant with a copper hemisphere and test disc.

How are temperatures measured?

Most units use thermocouples with a multichannel digital temperature indicator, for example 8 along the metal rod and 7 along the natural convection pipe. The heat exchangers use thermometers for inlet and outlet water, with a digital indicator offered as an option on the plate type.

Related engineering ranges

Return to the Engineering Lab range, or see the Theory of Machine Lab and Fluid Mechanics Lab subcategories for the other core mechanical engineering laboratories.

Quotations for heat transfer apparatus are prepared from the EL-HTL codes and quantities sent to [email protected] or through the Contact page.

Lagged Pipe Apparatus

Product Code : EL-HTL-11079

Floor Area-1.5 Meter X 1 Meter X 0.5 Meter High

Note:

View Details

Composite Walls Apparatus

Product Code : EL-HTL-11078

Heat conduction set-up with a 250 mm mica heater between MS, bakelite and brass/aluminium plates, dimmerstat, voltmeter, ammeter and digital temperature indicator.

Note:

View Details

Heat Pipe Apparatus

Product Code : EL-HTL-11080

Stainless steel heat pipe, 25 mm OD x 450 mm, evacuated and water-charged, tested beside identical copper and SS pipes with band heaters and water heat sinks.

Note:

View Details

Critical Radius Of Insulating Material

Product Code : EL-HTL-11081

Four GI pipes with internal heaters, each lagged with plaster of Paris to a different thickness, with separate dimmerstats and a digital temperature indicator.

Note:

View Details

Pin Fin Apparatus

Product Code : EL-HTL-11082

Interchangeable MS, brass and aluminium pin fins in a 150 x 100 x 1000 mm duct with band heater, 5 thermocouples, FHP blower and orifice meter.

Note:

View Details

Natural Convection Apparatus

Product Code : EL-HTL-11083

Vertical brass pipe, 38 mm OD x 500 mm, with cartridge heater and 7 thermocouples, in a 200 x 200 x 800 mm enclosure with a Perspex side.

Note:

View Details

Forced Convection Apparatus

Product Code : EL-HTL-11084

32 mm NB GI test pipe, 500 mm long, with external band heater, centrifugal blower and flow control valve, orifice meter and multichannel digital temperature indicator.

Note:

View Details

Specific Heat Of Air Apparatus

Product Code : EL-HTL-11085

Blower-driven air duct with orifice meter, 1 kW central heating coil, 0-300 deg C multichannel digital indicator, voltmeter and ammeter for finding cp of air.

Note:

View Details

Heat Transfer in Agitated Vessel:

Product Code : EL-HTL-11087

Insulated 20 litre heated vessel with a 200 mm, 8-turn copper helical coil, 150 mm agitator on a 1/8 HP motor, separate controllers and temperature indicator.

Note:

View Details

Emissivity Measurement Apparatus

Product Code : EL-HTL-11088

Two 160 mm aluminium plates, a test plate and a black plate, each with a mica heater and its own dimmer, in a Perspex-fronted panel with digital temperature indicator.

Note:

View Details

Stefan Boltzmans Apparatus

Product Code : EL-HTL-11089

Water-jacketed 200 mm copper hemisphere heated by immersion heater, 20 mm copper test disc with centre thermocouple, 0.1 deg C digital indicator and 5 s buzzer.

Note:

View Details

Critical Heat Flux Apparatus

Product Code : EL-HTL-11090

Pool boiling set-up with a 10 cm test wire of 35 or 40 gauge in a glass trough, 1 kW nichrome water heater, dimmerstat, voltmeter, ammeter and table light.

Note:

View Details

Concentric Tube Heat Exchanger

Product Code : EL-HTL-11091

Double pipe heat exchanger with a 12.7 mm ID copper inner tube inside a GI outer pipe, 1.5 m long, with four thermometers and a 3 kW geyser.

Note:

View Details

Shell Tube Heat Exchanger Water To Water

Product Code : EL-HTL-11092

Water-to-water shell and tube heat exchanger with a 150 NB, 750 mm shell, copper tubes on triangular pitch, four 25% cut baffles and a 3 kW heater.

Note:

View Details

Plate Type Heat Exchanger Apparatus

Product Code : EL-HTL-11093

Counter-flow stainless steel plate heat exchanger with 200 x 400 mm plates, a 3 kW geyser, flow control valves and a calibrated flow measuring vessel.

Note:

View Details

Thermal Conductivity Of Metal Rod

Product Code : EL-HTL-11094

Apparatus with a 25 mm copper bar, eight thermocouples, band heater, water-cooled heat sink, dimmerstat and digital temperature indicator for conduction tests.

Note:

View Details

Office Address

Works:11/315, Lalita Park, Laxmi Nagar, Delhi, 110092

[email protected]

Follow Us